1,保证负离子检测仪电量充足,检测仪上面的红绳需解除。晴天测试数据较好,阴雨天气负离子数据可能偏低。仪器切勿放在施工的房间,以免产品施工中的雾状气体进入仪器,影响仪器正常运行。
1, ensure that the anion detector has enough power, and the red rope on the detector must be removed. Clear weather test data is good, negative weather data may be low in rainy weather. The instrument should not be placed in the construction room, so as to avoid the misty gas entering the instrument during the construction and affect the normal operation of the instrument.
2,仪器从室外温度较高的地方拿到房间内使用时,仪器需要时间适应室内外环境温度的差异。把仪器电源打开,待屏幕上数值稳定后静待45分钟左右,再进行绝对归零调试。
2, when the instrument is used in the room with higher outdoor temperature, the instrument needs time to adapt to the difference of temperature between indoor and outdoor environment. Open the instrument power and wait for 45 minutes until the screen is stable. Then absolute return to zero debugging is done.
3,为保证负离子的释放量,墙面喷涂“家65”产品时一定要均匀饱满,中间不能有空隙。房间内的所有的墙面尽量喷涂到位,包括屋顶也要喷涂。
3, in order to ensure the release of negative ions, the wall should be evenly and fully plastering when spraying "home 65" products, and there should be no gaps between them. All the walls in the room should be sprayed as far as possible, including the roof.
负离子检测仪如何使用
How to use negative ion detector
1,需要在普通环境或者没有喷洒家65普通房间内进行绝对归零调试。
1, it is necessary to carry out absolute return to zero debugging in 65 ordinary rooms without ordinary sprinkler.
先开机,等待3-5分钟,待屏幕上数字稳定后,再进行绝对归零调试。按一下归零按键,然后快速按两下平均值,测试仪屏幕上显示6个C时方为绝对归零操作成功。
First boot, wait for 3-5 minutes, until the screen is stable, then absolute return to zero debugging. Press the zeroing button, and press the average of two quickly. When the 6 C is displayed on the tester screen, the absolute return to zero operation is successful.
2,在没有喷洒家65的房间对负离子仪器进行调试时,人需要远离测试仪1米以外,待平均值稳定在700以下后,方可携带测试仪进入喷洒家65的房间进行测试。
In 2, no 65 room spray to debug the negative ion instrument, people need to stay away from the tester 1 meters away, the average value below 700, can carry 65 tester sprayed into the test room.
3,家65使用后,对房间进行负离子测试时,关闭门窗,不得开启空调。
3, when the home 65 is used, when the room is tested for negative ions, close doors and windows, and do not turn on the air conditioner.
4,测试贴墙数据时,需在喷刷完毕20分钟后开始测试,以防涂层中的雾状气体进到测试仪器里面,影响数据。
4, when testing the wall data, it is necessary to start testing after 20 minutes of spraying, so as to prevent the mist gas in the coating from entering the test instrument and affect the data.
将测试仪放在50公分以上的物体上(不要直接放到地面上),与墙面60度角测试,室内无人和无其他特别污染源的情况下,连续测试8小时以上平均值的数据,平均值自会稳定在3000以上。
The tester on the 50 cm above the object (not directly on the ground), and the wall of 60 degree angle test, and no other special pollution source of the indoor unmanned, continuous testing for more than 8 hours the average value of the data, the average value will be stabilized at more than 3000.
5,测试空气中的负离子浓度是在房间喷涂率超过70%(喷涂墙体总面积约为建筑面积的三倍)以上实测所得。
5, the concentration of negative ions in the air is measured over 70% of the room spraying rate (three times the total area of the spray wall is about the construction area).
6,上述空气中的负离子浓度是指在房子中间离地1.3米高度实测所得,该数据受该空间涂刷比例以及环境中其他物品释放的有毒有害气体的数量影响较大,随着有毒气体被降解得越来越多,负离子数据也会越来越高。
6, the concentration of negative ions in the air is in the middle of the room is 1.3 meters height measured by the data, determines the amount of toxic and harmful gases and other items of the space and environment in the release of brushing ratio is larger, with the degradation of toxic gas is more and more negative ion data will be increasingly high.